Home ProductsReverse Osmosis Water Treatment System

Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency

Certification
China Jiangsu Zhongyin Machinery Co.,Ltd certification
China Jiangsu Zhongyin Machinery Co.,Ltd certification
Customer Reviews
This is a professional manufacturer! I am satisfied with your surface treatment technology!

—— Mohammed Mobaidin

Thanks very much for your perfect quality and VIP service, we will keep contract and do more business with you!

—— Mark From USA

We received your drinking water filling machine last thursday and we are very pleased with the quality of your product.

—— Lionel Lobo

I'm Online Chat Now

Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency

Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency
Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency

Large Image :  Commercial Reverse Osmosis Water Treatment System Two Stage High Efficiency

Product Details:
Place of Origin: Jiangsu province
Brand Name: China beverage
Certification: CE ISO
Model Number: RO
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 45-90 Working Days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 100 sets per year
Detailed Product Description
Material: Stainless Steel 304/316 Ro Membrane: Hydraulics Or DOW
Capacity: 1t/h-100t/h Product Name: Water Purification System
Application: Pure Water Filling Line Function: RO Purification Water
Type: Reverse Osmosis
High Light:

reverse osmosis system

,

reverse osmosis filtration system

Commercial Two Stage Reverse Osmosis Drinking Water Purification System

 

Introduction

Two-stage RO system is widely used in preparation of water for beverage industry, which features adaptable of different salt content of water, easy operation, less labor force and low running cost.


Composition

1. Pre-treatment System.

Pre-treatment system is composed of quartz sand filter, active carbon filter, softener and precision filter. The water temperature requires

25± 30C.

Flocculator is used for destroying electro-neutral of colloid in water, which ensures raw water can reach to the requirement of Silt Density Index(SDI)≤ 4. Mechanical filter can remove most of suspension, colloid and grain impurity, which can ensure initial purification of water.

If some of raw water comes from tap water, chlorine content maybe is higher. Low-pressure compound RO membrane has strict limitation to chlorine and organism, which must be ≤ 0.1mg/1.

Because calcium and magnesium content in raw water is very high, and RO salt-removing rate is about 97%, which may cause deposit of calcium carbonate, magnesium carbonate, bitter salt, etc. On concentrated water side. Deposit adhered on RO membrane surface and may block passage of components and causes pressure difference increase, water output decrease and salt-removing rate decrease, which influences normal running and usage span of RO. So before precision filter, Scale Inhibitor is equipped to protect and avoids impurity on RO concentrated water side.

2. Reverse osmosis System

RO system is composed of high-pressure pump, two-stage RO system and chemical cleaning device.

two-stage RO system can remove salt over 99% and 100% organisms. During running, RO membrane may form some deposit and chemical cleaning device is equipped for periodical cleaning to ensure stable running of RO system. This system configures with Hydranautics ESPA1 membrane compounds (USA) and Grundfos high-pressure pump (Denmark).

High-pressure pump is the power source of RO system. To RO system on sound running condition, high-pressure pump equips inlet/outlet pressure switch. When inlet pressure is less than set value (water lack P≤ 0.05Mpa) or outlet pressure is higher than set value, pressure switch send signal to PLC programming system and high-pressure pump and RO system will stop in avoidance of destroying to RO membrane because of water pressure.

RO system pressure control and automatic cleaning are controlled by PLC. RO system can wash surface of RO membrane by low-pressure timely and periodically.

This water treatment capacity is 10 m3/h. Salt-removing rate is over 99.0% and water recycling rate is 75%.

Specifications

 

 

No. Name / Specification Unit Qty.
  1. Technical Equipments    
1 Raw Water Tank Vn=5m3 unit 1
2 Raw Water Pump unit 1
3 Mechanical Filter unit 1
4 Active Carbon Filter unit 1
5 Softener unit 1
6 Precision Filter unit 1
7 2-stage RO System unit 1
8 Central Water Tank unit 1
9 Pump unit 1
10 Oxidation Tower unit 1
11 Ozonizer unit 1
12 Pure Water Tank unit 1
13 Pump unit 1
14 Ti-rod Filter unit 1
  2. Material    
  Refined Sand 0.4-0.6mm ton  
  Active Carbon 0.6-0.8mm ton  
  Positive Resin 001& times; 7 ton  
  3. Pipelines and Valves set  